The HPE ProLiant DL360 server is designed to deliver security, agility and flexibility without compromise. This rack server provides the right balance of expandability and density.
HP ProLiant DL360 Quick Specs
Height | 1.70″ |
Width | 16.78″ |
Depth | 27.75″ |
Weight | 37lbs |
Wattage | 854W |
Voltage | 90-132 VAC, 47-63Hz |
Heat Dissipation | 2916 BTU/hr |
Operating Temperature | 50F to 95F |
Acoustical Noise Emissions | 6.4 bel (64 dB) |
HP Documentation | DL360 Quick Specs |
HP ProLiant DL 360 Quick Rails
The DL360 is one of HPs most popular 1U Rackmount Servers. This server is best suited for the entry level small business client that is not looking to purchase equipment that will run multiple enterprise applications. This server is ideally suited as an economical web server. Here are some HP DL360 4Post Installation Options below for your reference.
Generation | Rail Kit | Notes |
DL360 G5p | HP Universal Rail Kit | The standard rail kit supports square or round holed racks with an installation depth of 22.25″ – 37.75″. |
DL360 G5 | HP Universal Rail Kit | The standard rail kit supports square or round holed racks with an installation depth of 22.25″ – 37.75″. |
DL360 G4 | HP Universal Rail Kit | The standard rail kit supports square or round holed racks with an installation depth of 22.25″ – 37.75″. |
DL360 G3 | HP Universal Rail Kit | The standard rail kit supports square or round holed racks with an installation depth of 22.25″ to 40″ |
DL360 G2 | HP Universal Rail Kit | The server ships with Fixed Rails which support several rack options |
Sliding Rail Option | The Slide Rail option is for square holed racks with an installation depth of approximately 29″. | |
2Post Rail Option | The 2Post Rail option supports uprights from 3″ to 6.5″ | |
3rd Party Rail Option | The 3rd Party Rail option supports round or square holed racks within installation depth from 28″ to 33″. | |
DL360 G1 | Call for Support |
HP ProLiant DL 360 Fixed Rail Kit
- Economically mounts the HP DL360 into any rack
- Does not require HP Rail Kit
- Compatible with any Standard 19″ Server Rack
- Cable Management Crossbar included
Equipment Depth | The Rack Rails support flange is 23 1/2″ (597mm) long. The Rack Rail will support servers computers or equipment up to 35″ (889mm) deep. |
Equipment Width | Maximum Equipment Width:17 5/8″ (448mm) 1U Fixed Rails Minimum Equipment Width:16 1/4″ (413mm) |
Weight Capacity | 1U Fixed Rails Maximum Equipment Weight: 45 lbs. |
Equipment Mounting | Rack Rails standard thumb screw threads (10-32, 12-24, and metric M6). |
Construction | The 1U Rack Rail is made of 0.049″ (1mm) steel with a durable zinc plating. |
Cable Management | Cable management bar included. Velcro® straps provided for securing cables. |
Hardware | Includes screws, cage-nuts, and nuts for all standard rack types (see below). |
HP ProLiant DL360 Quick Rail Kit (2Post Relay Rack)
- HP DL360 installed in a 2Post Relay Rack
- HP Quick Rail Kit is required
- Compatible with 3″ Upright Relay Racks
- The Conversion Kit will mount 2 DL360’s
2Post Conversion Kits are available in a variety of sizes ranging from 2U to 7U. These kits allow for the use the HP Quick Rails that are designed to go into a 4Post Server Rack. HP no longer manufactures Rail Kits for 2Post Relay Racks. Instead HP utilizes the RackSolutions product line of 2Post Conversion Kits for all of their 2Post Relay Rack installations.
HP DL360 Fixed Rail (Relay Rack Kit)
- The DL360 from HP can be installed into any 2Post Relay Rack
- This Rail Kit does not require the HP Quick Rail Kit
- Compatible with any size Relay Rack
- Provides 1U Rack Mount Space
The 1U Fixed Rail is a generic product that will allow the DL360 as well as a wide assortment of other products to be installed into any type of Relay Rack. This Rail Kit does not require the HP DL360 Quick Rail Kit for installation. The versatility of this 1U Fixed Rail Kit allows for center mounting as well as flush mounting equipment in to a 2Post Relay Rack.